Category ->
VACUUM PUMPS ->
END SUCTION VACUUM PUMPS TYPE : DV SERIES
END SUCTION VACUUM PUMPS TYPE : DV SERIES
|
 |
RANGE |
Vacuum : up to 650 mm of Mercury Air flow rate : up to 162 m3 / hr Power rating : 3.7 kW to 7.5 kW (5.0 HP to 10.0 HP) |
FEATURES |
- Sturdy casing, provided with foot, suction and delivery nozzles
- Rotor having outwardly bent multi blade sdsign held on shaft by shaft sleeve nus.
- Deep stuffing boxes are provided to prevent entry of external air.
- Long life-Due to replaceable wearing parts.
- Dynamically balanced rotating parts ensure minimum vibrations.
- Easy maintenance and spares availability
|
APPLICATIONS |
- Priming of large pumps.
- Evacuation of air from suction pipes and chambers
- General application : Drying, Evaporation, Distiltation, Filtration, Sterilisation, Condensation, Degasification, sucking gases.
- Specific applications : Twist drilling machine, removing water from pulp layer, labeling, bottle filling, de-odorising.
|
APPROXIMATE PERFOMANCE OF 'DV' Series, Coupled, End Suction Vacuum Pumps, at rated speed. |
PUMP MODEL |
HP |
SUC. |
DEL. |
VACUUM IN MM OF MERCURY |
100 |
200 |
300 |
400 |
500 |
600 |
700 |
750 |
AIR FLOW RATE IN CUBIC METRES PEUR HOUR |
DV 40 |
5 |
40 |
40 |
0 |
13 |
27 |
38 |
49 |
59 |
68 |
73 |
DV 50 |
10 |
50 |
50 |
0 |
27 |
53 |
76 |
98 |
124 |
146 |
162 |
|